Air Pollution Control System
Air Pollution Control System Supplier
Pollution-Free Air Solutions
Advanced air pollution control solutions create a cleaner, healthier society by reducing pollutants and improving air quality.
What We Do
In the fruitful year of 2024, we,Skant&Co.(Sister Concern) have stepped into a strategic partnership with an ISO Certified Company name as Unicon Engineers for their existing offerings in the market like ESP (Electrostatic Precipitator), Bag Filter/Bag Houses/ DE Systems/ Dust Extraction Systems/ De- Dusting Systems, Pneumatic Conveying System, and many more. They have been serving with their pioneer services for more than 3 decades. The vast pool of expertise already mobilized form various fields of Design, Manufacturing, project management, servicing, up-gradation of air pollution Control system equipment’s and global presence over 25+ countries across the world.
OUR PRODUCTS:
Electrostatic Precipitators (ESP ) :
An Electrostatic Precipitator (ESP) is an air-pollution control device used in industries to remove fine dust, smoke, and particulate matter from exhaust gases by using electrical charges. It works by charging particles electrically and then collecting them on oppositely charged metal plates, ensuring clean gas is released into the atmosphere.
Our types of Electrostatic Precipitators
Dry Electrostatic Precipitators
Designed to remove dry particulate matter, such as dust and ash, from industrial exhaust streams. They work by passing dirty gas between electrically charged plates and collecting the particles on those plates.
Wet Electrostatic Precipitators
Used for removing wet and sticky particles like oil, tar, or paint from gas streams. They operate similarly to dry ESPs but use moisture to help collect the particulate matter.
Plate Electrostatic Precipitators
These use a series of flat plates to collect particles. They are commonly used in power plants because they can handle large volumes of gas and high particulate concentrations.
ONE STEP SOLUTION FOR ALL YOUR ENVIROMENTAL NEED.
Electrostatic Precipitators (ESP ) :
- ESPs for Sinter Plant (Head end & Tail End)
- ESPs for Pellet Plant (Hood & Wind Exhaust)
- ESPs for 2 x 1000 TPD DRI WHRBs
- ESPs for 1 x 1000 TPD DRI WHRBs
- ESPs for 6 x 650 TPD DRI WHRBs
- ESPs for 2 x 650 TPD DRI WHRBs
- ESPs for 1 x 650 TPD DRI WHRBs
- ESPs for 2 x 500 TPD DRI Kilns
- ESPs for 2 x 350 TPD DRI WHRBs & 1 x 30MW CFBC Boiler
- ESPs for 2 x 250 TPH CFBC Boiler (Char & Coal)
- ESPs for 2 x 500 60TPH (100% Char Fired) AFBC Boiler
- 30+ ESPs for DRI Kiln WHRBs &Dolochar Fired Boilers
- 500+ ESP Retrofit Installations.
*Others Industry —
- Cement: Klin, Mills,Cooler;
- Iron & Steel: Sintering, Pelletization,Sponge Iron Kiln,Cast House,Stock House;
- Biomass Fired Boilers;
- Waste To Energy Plants;
- Pulp & Paper: Recovery Boiler, Lime Kiln;
- Non-Ferrous: Smelter, Converter;
- Oil & Gas: FCCU etc;
| Parameter | Data |
| Application | Power Plants – Boilers and Heaters, *Other Industries |
| Capacity (Power Plant MW) | 5 to 600 |
| Gas Temperatures(°c) | 70 – 400 |
| Gas Flow Rate(m3/s) | 5 – 1500 |
| ESP inlet dust loading (g/Nm3) | 0.2 – 250 g/Nm3 |
| Guaranteed ESP outlet emission (mg/Nm3) | 10 – 200 (suitable design for ESP as per – collector),filterable PM only |
| PM Collection Efficiency | Up to 99.95% |
| Availability | Up to 98% |
Fume Extraction & Collection System :
Product Overview
Our Fume Extraction & Collection System is engineered to efficiently capture, filter, and eliminate hazardous fumes, smoke, and airborne particles generated during industrial processes. Designed for high performance and durability, the system ensures a safe, clean, and compliant working environment across various industries.
Key Features
- High-efficiency fume and dust extraction
- Robust construction with long service life
- Advanced filtration technology (Bag / Cartridge / HEPA)
- Energy-efficient high-performance blowers
- Modular and customizable design
- Low maintenance and easy operation
- Compliance with environmental and safety standards
Technical Specifications
Parameter | Specification |
Air Flow Capacity | 500 – 50,000 CMH (customizable) |
Static Pressure | Up to 1500 mm WC |
Filtration Efficiency | Up to 99.9% |
Filter Type | Cartridge / Bag / HEPA |
Blower Type | Centrifugal |
Duct Material | GI / MS / SS |
Noise Level | ≤ 85 dB |
Power Supply | 415V / 50Hz / 3 Phase |
Automation | Optional PLC-based control |
System Components
- Extraction Hood / Arm – Captures fumes at source
- Ducting Network – Transfers contaminated air
- Dust / Fume Collector – Removes particles
- Blower / Fan – Generates suction
- Filter Unit – Purifies air
- Chimney / Exhaust Stack – Safe air discharge
Advantages
- Ensures a healthier workplace
- Reduces environmental pollution
- Improves operational efficiency
- Minimizes equipment damage due to dust
- Meets statutory compliance requirements
Optional Features
- Pulse jet automatic cleaning system
- Spark arrestor
- Acoustic enclosure for noise control
- Wet scrubber attachment for chemical fumes
- Air quality monitoring system